The Data Logger board has a CAN interface with support for a wide range of protocols and standards, including J1939 for generators/engines, NMEA 2000 for vessel data and proprietary protocols like Victron's VE.Can and PylonTech BMS.
J1939
PGN | Name | Data |
---|
65262 0xFEEE | Engine Temps 1 | Engine coolant temperature, engine oil temperature |
65253 0xFEE5 | Engine Hours | Total Engine Hours |
65263 0xFEEF | Fluids & Pressures | Engine Oil Level % |
61444 0xF004 | Engine Controller 1 | Engine Load %, Engine RPM |
NMEA 2000
| PGN | Name | Data |
| 127508 0xF214
| Battery Voltage, Current, Power, Temperature |
| 127506 0xF212
| Battery State of Charge, State of Health |
| 65014 0xFDF6
| AC Quantities Line to Line, Line to Neutral, Current |
| 65016 0xFDF8
| AC Power (Inverter, Generator, Shore/Grid) |
| 65013 0xFDF5
| AC Power (Inverter, Generator, Shore/Grid) |
| 61953 0xF201
| Engine Data (Oil Pressure, Coolant Temperature, Load %) |
| 128259 0xF503
| Boat Speed over Group, Speed through Water |
| 130306 0xFD02
| Wind Speed & Angle |
| 61969 0xF211
| Tank Level & Type |
BMS / Battery Data
PGN | Vendor | Data |
---|
853 0x355 | PylonTech | State of Charge, State of Health |
854 0x356 | PylonTech | Pack voltage, current and temperature |
1067 0x42B | PylonTech | Battery Status (V, I, SOC) |
833 0x341 | Wattius | Pack Voltage, Current, Capacity, SOC |
Victron Registers
Register High | Low | Data |
---|
0xED | 0x7D | Battery Voltage |
0xED | 0x8F | Battery Current |
0x10 | 0x01 | Charged Voltage |
0x10 | 0x02 | Charged Current |
0x0F | 0xFF | Battery State of Charge |
0xEE | 0xFF | Consumed AH |
0x01 | 0x00 | Product ID |